Blue Line™ D1-P TriTech® Detector Installation Instructions
Bosch Security Systems
Blue Line™ is a trademark of Bosch Security Systems in the United States and other countries.
TriTech® and Pet Friendly® are registered trademarks of Bosch Security Systems in the United States.
1 Specifications
Microwave
- Blue Line D1-P1-F1 10.525 GHz
- Blue Line D1-P1-F2 10.588 GHz
- Blue Line D1-P1-F3 9.9 GHz
Input Power
- 10 VDC to 14 VDC
Current Draw
- 15 mA @ 12 VDC standby
- Alarm current 22 mA
Standby Power
- No internal standby battery. For UL Listed Product Installations, 4 hours (20 mAh) standby power must be provided by the control unit or by a UL Listed burglary power supply.
Relay
- Solid State Supervised Form “A” normally-closed (NC) rated for 125 mA at 28 VDC, 3 W.
Tamper
- NC (with cover on) contacts rated at 28 VDC, 125 mA maximum. Connect tamper circuit to a 24-hour protection circuit.
Digital Alarm Output
- 5 V normally, ground during alarm
Supervision
- The unit is tested every 3 h. If the microwave fails, the PIR continues to operate.
Temperature
- -20°F to +120°F (-29°C to +49°C)
- For UL Listed installations, the temperature range is +32°F to +120°F (0°C to +49°C)
Humidity
- 0 to 95% non-condensing
Dimensions
- 5.2 in. x 2.4 in. x 1.9 in. (13.2 cm x 6.1 cm x 4.8 cm)
Pet Immunity
- Bosch Security Systems Pet Friendly® Blue Line D1-P TriTech Detector does not detect one to two pets up to 100 lb (45 kg) total or numerous rodents. The pet immunity feature was not tested by UL.
Options
- B335 Low Profile Swivel Mount Bracket, B328 Gimbal Mount Bracket, and B338 Ceiling Bracket. These brackets can reduce the detector’s range and increase the dead zone area.
- Note: You cannot use a camera with the B338 Ceiling Mount Bracket.
Compliance
- This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry and Science Cananda. Operation is subject to two conditions:
- This device cannot cause harmful interference.
- This device must accept any interference, including interference that might cause undesired operation.
- Changes or modifications not expressly approved by Bosch Security Systems can void the user’s authority to operate the equipment.
- Use only a Listed limited-power source.
- Connect all wiring to a safety extra-low voltage (SELV) circuit only.
2 Installation Considerations
- Not suitable for outdoor use (2-1).
- Never install the detector where the PIR or microwave is in constant alarm (LED on). The LED is off when properly installed.
- Point away from outside traffic. Microwave energy passes through non-metallic walls.
- Point away from direct and indirect sunlight (2-2).
- Point away from glass or other objects that rapidly change temperatures (2-3, 2-4, and 2-5).
- Point away from rotating machines (fans) (2-6).
3 Coverage Patterns
- Top view (3-1)
- Side view (3-2)
- Optional look-down (3-3)
- Microwave coverage
- PIR coverage
4 Mounting Considerations
- Insert a flat head screwdriver in slot (4-1) and lift to open cover.
- Select a mounting location. Mount the sensor where an intruder is most likely to cross the coverage pattern (4-2).
- Mount the detector 7.5 ft to 9 ft (2.25 m to 2.7 m) above the floor (4-3).
- Pet mounting recommendations:
- Range of pet immunity (4-4).
- Do not point the detector where pets can climb (4-5).
5 Mounting
- Optional: Mount the detector temporarily by peeling the blue tape off the back of the base to expose the adhesive. Do not use where adhesive can damage the wall.
- Mount the base using one of these options:
- for surface or corner mounting, use the appropriate mounting holes (5-1) and the screws provided.
- use the optional B335 Bracket here (5-2).
- use the optional B328 Bracket here (5-3).
- use the optional 338 Bracket here (5-4)
- Note: Do not over tighten the mounting screws. The cover might not attach correctly.
- For the wall tamper function, insert the two pan head screws through the wall tamper knockouts (5-6). If needed, use the anchors provided to secure the unit.
- Wire the detector base. Thread the wires through the appropriate diameter wire knockouts on the detector base (5-7) or on the removable top insert (5-8).
- When wiring from below, thread wiring through these wire knockouts that are perpendicular to the base (5-9).
- Use the cable ties (5-10) for strain relief.
6 Terminal Block Wiring
Terminal block (5-11) wiring:
- 6 VDC to 15 VDC (6-1)
- NC alarm contacts (6-2)
- NC tamper contacts (6-3)
- Digital alarm output (6-4)
7 LED Operation
- Select LED (7-1) operation:
- Jumper position for LED on (7-2)
- Jumper position for LED off (7-3)
- Turn the microwave range to minimum (7-4). Perform a Walk Test to set the appropriate range for your installation.
- Non-pet installations only: Create a look-down zone directly below the detector by removing the tape covering the lens (7-6) on the inside of the front cover.
- Note: You cannot cover the look-down zone once the tape is removed.
- Replace the cover.
- To lock the cover (optional):
- Press the top of the cover tab (7-7) with your finger to lift the lower edge.
- Lift the lower end of cover tab with your finger (7-8) to open it.
- Insert a flat head screwdriver in the slot (7-9) in the cover tab opening and turn it 180° to lock the cover. Indicator points down (7-10).
8 LED Display
The Blue Line D1-P has blue, yellow, and green LEDs that light for various alarm and supervision trouble conditions.
- LED off.
- LED on.
- LED sequence.
- Walk Test disabled.
- Walk Test enabled, power up.
- Walk Test enabled, dual alarm.
- Walk Test enabled, microwave alarm.
- Walk Test enabled, PIR alarm.
- Walk Test enabled, no activity.
9 Walk Test
Note: Ensure the LED jumper is set to on (7-2).
Note: To avoid false alarms, set the microwave range (7-4) to its minimum setting before starting the Walk Test.
- Microwave coverage
- PIR coverage
- Wait at least 2 minutes after power up to start the Walk Test.
- The blue, yellow, and green LEDs light in sequence until the detector stabilizes and no movement is detected for 2 seconds.
- The LEDs do not light when there is no motion.
- Enable the Walk Test from the keypad.
- Observe the LED as you walk to the farthest edge of the pattern. Walk closer to the detector by crossing the pattern (8-1).
- The green LED lights, identifying the PIR pattern edge.
- The yellow LED lights, identifying the microwave pattern edge.
- The blue LED indicates alarms in both the microwave and PIR mode.
- Repeat Step 3 from the opposite side.
- If the required range is not achieved, increase the microwave adjustment (7-5) by turning it counter-clockwise slightly.
- Repeat the walk test and adjustments until you reach the farthest edge of coverage needed.