Bosch Commercial Series TriTech AM Motion Detectors with Anti-mask

Models Covered

  • ISC-CDL1-WA15G
  • ISC-CDL1-WA12G
  • ISC-CDL1-WA15GE
  • ISC-CDL1-WA15HE
  • ISC-CDL1-WA15G-CHI

Overview and Installation Recommendations

This Quick Installation Guide provides essential information for setting up your Bosch TriTech AM Motion Detectors. Key recommendations include:

  • Recommended Mounting Height: 2.3 m - 2.75 m (7.5 ft - 9 ft), with 2.3 m (7.5 ft) being ideal.
  • Environmental Conditions: 0-95% Relative humidity, non-condensing.
  • Mounting Considerations: Avoid obstructions, direct sunlight, and heat sources for optimal performance. Ensure proper sealing to maintain IP/IK ratings.
  • The detector should be mounted within 30 cm (1 ft) from a wall if relevant for the specific model/installation.

Wiring Configurations

The detectors support various wiring configurations, often utilizing End-Of-Line (EOL) resistors for supervision. Common terminal connections include:

  • Power: 9 to 15 VDC
  • Alarm Output: NC (Normally Closed)
  • Tamper Output: T, TR

Different resistor values (e.g., 1kΩ, 2.2kΩ, 12kΩ, 33kΩ) are shown for different Grade levels and supervision requirements. Ensure correct resistor placement as per system specifications.

LED Indications: The device features LEDs for status indication (ON/OFF) during operation and walk tests.

Adjustments and Settings

  • Sensitivity: Adjustable via MIN/MAX settings.
  • Pulse Count/Timing: Settings like "2 min", "2 s", "2 s" are indicated, likely for walk test or pulse processing.
  • EN Grade Certification:
    • C2DT EN Grade 3 (High)
    • C2DT EN Grade 2 (Low)
    Note: C2DT Low EN Grade 2 and Switch 3 were not investigated by UL.

Technical Specifications

  • Microwave Frequency: 10.570 to 10.610 GHz
  • Microwave Power: <20 mW (for ISC-CDL1-WA15HE)

Regulatory Compliance and Certifications

The Bosch TriTech AM Motion Detectors comply with various international standards and certifications:

European Union (EU)

  • CE: Complies with RED (2014/53/EU) and RoHS (2011/65/EU and 2015/863).
  • EN 50131-2-4: Grade 3 (for ISC-CDL1-WA15GE, ISC-CDL1-WA15HE).
  • EN 50130-5: Environmental Class I (ISC-CDL1-WA15HE) and Class II (ISC-CDL1-WA15GE).
  • Ingress Protection: EN60529, EN62262: IP41 / IK04.

United States (USA) & Canada (CA)

  • UL/C-UL: UL639, C-UL S306-03 LISTING for Intrusion Detection Unit, Type: S (ISC-CDL1-WA15G, ISC-CDL1-WA12G).
  • FCC: Part 15 Subpart B & C, Class B, FCCID: T3X-CDL1 (ISC-CDL1-WA15G).
  • IC (Industry Canada): RSS210 1249A-CDL1 (ISC-CDL1-WA15G). This device complies with part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

France (FR)

  • AFNOR EN50131-2-4 Grade 3, NF324-H58 & CNPP + RTC 50131-2-4: Specific certification for anti-masking, magnetic immunity, and self-supervision for opening.
  • NF Certificate: #2830200012 for ISC-CDL1-WA15HE.

Australia (AU)

  • ACMA: RCM (ISC-CDL1-WA15G, ISC-CDL1-WA12G).

Brazil (BR)

  • ANATEL: Resolution No. 242 (ISC-CDL1-WA15G, ISC-CDL1-WA12G). This equipment operates on a secondary basis and does not have protection against harmful interference from stations of the same type and cannot cause interference to primary operating systems.

China (CN)

  • CCC: 2015031901000145 (ISC-CDL1-WA12G-CHI, ISC-CDL1-WA15G-CHI).

Detection Coverage Patterns

The document includes diagrams illustrating the detection coverage patterns for various models, showing typical ranges in both feet and meters. These patterns vary based on the specific model (e.g., ISC-CDL1-WA15G, ISC-CDL1-WA12G) and provide guidance for optimal placement within the surveillance area.